0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HO 60-P-0100

HO 60-P-0100

  • 厂商:

    LEM(莱姆)

  • 封装:

  • 描述:

    LEM - HO 60-P-0100 - Current Transducer, HO-P Series, PCB, 60A, -150A to 150A, 1.25 %, Voltage Outpu...

  • 数据手册
  • 价格&库存
HO 60-P-0100 数据手册
IPN = 60, 100, 120, 180, 240, 250 A Current Transducer HO-P series Ref: HO 60-P, HO 100-P, HO 120-P, HO 180-P, HO 240-P, HO 250-P For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Applications ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● Open loop multi-range current transducer Voltage output Single power supply +5 V Over-current detect 2.93 × IPN (peak value) EEPROM Control Galvanic separation between primary and secondary circuit Low power consumption Compact design for THT PCB mounting Aperture: 15 × 8 mm Factory calibrated Dedicated parameter settings available on request (see page 12). Advantages ●● ●● ●● ●● Low offset drift Over-drivable Vref 8 mm creepage/clearance Fast response. AC variable speed and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Combiner box MPPT. Standards ●● ●● ●● ●● EN 50178: 1997 IEC 61010-1: 2010 IEC 61326-1: 2012 UL 508: 2010. Application Domain ●● Industrial. N°97.K4.27.000.0; N°97.K4.34.000.0; N°97.K4.36.000.0; N°97.K4.42.000.0; N°97.K4.D4.000.0; N°97.K4.45.000.0 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 1/15 www.lem.com HO 60 .. 250-P series Absolute maximum ratings Symbol Unit Supply voltage (not destructive) Parameter UC V 8 Supply voltage (not entering non standard modes) UC V 6.5 Primary conductor temperature TB °C 120 UESD kV 2 ESD rating, Human Body Model (HBM) Value Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may degrade reliability. UL 508: Ratings and assumptions of certification File # E189713 Volume: 2 Section: 5 Standards ●● CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01 ●● UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15 Ratings Parameter Symbol Primary involved potential Unit Value V AC/DC 600 Max surrounding air temperature TA °C 105 Primary current IP A According to series primary current Secondary supply voltage UC V DC 5 Output voltage Vout V 0 to 5 Conditions of acceptability 1 - These devices have been evaluated for overvoltage category III and for use in pollution degree 2 environment. 2 - A suitable enclosure shall be provided in the end-use application. 3 - The terminals have not been evaluated for field wiring. 4 - These devices are intended to be mounted on a printed wiring board of end use equipment. The suitability of the connections (including spacings) shall be determined in the end-use application. 5 - Primary terminals shall not be straightened since assembly of housing case depends upon bending of the terminals. 6 - Any surface of polymeric housing have not been evaluated as insulating barrier. 7 - Low voltage control circuit shall be supplied by an isolating source (such as a transformer, optical isolator, limiting impedance or electro-mechanical relay). 10 - The jumper installed within the primary hole is only intended for fixing the sensor and not for carrying the primary current. Marking Only those products bearing the UR Mark should be considered to be Listed or Recognized and covered under UL's Follow-Up Service. Always look for the Mark on the product. Page 2/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HO 60 .. 250-P series Insulation coordination Parameter Symbol Unit Value Rms voltage for AC insulation test 50/60 Hz/1 min Ud kV 4.3 Impulse withstand voltage 1.2/50 µs ÛW kV 8 Partial discharge extinction rms voltage @ 10 pC Ue V > 1170 Clearance (pri. - sec.) dCI mm >8 Shortest distance through air Creepage distance (pri. - sec.) dCp mm >8 Shortest path along device body Clearance (pri. - sec.) - mm >8 When mounted on PCB with recommended layout Case material - - V0 according to UL 94 Comparative tracking index Comment Busbar / Secondary + jumpers 600 CTI Application example - - 600 V CAT III PD2 Reinforced insulation, non uniform field according to EN 50178, EN 61010 Application example - - 1000 V CAT III PD2 Based insulation, non uniform field according to EN 50178, EN 61010 Application example - - 600 V CAT III PD2 Simple insulation, non uniform field according to UL 508 Symbol Unit Min Ambient operating temperature TA °C −40 105 Ambient storage temperature TS °C −40 105 Mass m g Environmental and mechanical characteristics Parameter Typ Max Comment 34 Page 3/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HO 60 .. 250-P series Electrical data HO 60-P-0100 At TA = 25 °C, UC = +5 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 13). Parameter Symbol Unit Primary nominal rms current IPN A Primary current, measuring range IPM A Number of primary turns NP - Supply voltage 1) UC V Current consumption IC mA Reference voltage (output) Vref Reference voltage (input) Min Typ Max Comment 60 −150 150 1 @ UC ≥ 4.6 V See application information 4.5 5 5.5 19 25 V 2.48 2.5 2.52 Internal reference Vref V 0.5 2.65 Vout − Vref V −2 2 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Allowed capacitive load CL nF 0 OCD output: On resistance Ron Ω 70 95 150 Open drain, active low Over operating temperature range OCD output: Hold time thold ms 0.7 1 1.4 Additional time after threshold has released EEPROM control Vout mV 0 50 Vout forced to GND when EEPROM in an error state 2) Electrical offset voltage @ IP = 0 A VOE mV −5 5 Vout − Vref @ Vref = 2.5 V Electrical offset current Referred to primary IOE A −0.375 0.375 Temperature coefficient of Vref TCVref ppm/K −170 170 −40 °C … 105 °C Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 −40 °C … 105 °C Offset drift referred to primary @ IP = 0 A TCIOE mA/K −5.625 5.625 −40 °C … 105 °C Theoretical sensitivity Gth mV/A Sensitivity error @ IPN εG % −0.5 0.5 Factory adjustment (straight bus-bar) TCG ppm/K −350 350 −40 °C … 105 °C Output voltage range @ IPM Temperature coefficient of G External reference Over operating temperature range 200 300 Series 2 5 Series 6 800 mV @ IPN 13.333 Linearity error 0 … IPN εL % of IPN −0.75 0.75 Linearity error 0 … IPM εL % of IPM −0.5 0.5 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.92 0.92 One turn Reaction time @ 10 % of IPN tra µs 2.5 @ 50 A/µs Response time @ 90 % of IPN tr µs 3.5 @ 50 A/µs Frequency bandwidth (−3 dB) BW kHz Output rms voltage noise (spectral density) (100 Hz … 100 kHz) eno µV/√ Hz Output voltage noise (DC … 10 kHz) (DC … 100 kHz) (DC … 1 MHz) Vno mVpp Over-current detect 100 Small signals 9.2 5.0 13.8 26.0 A 2.64 × IPN 2.93 × IPN 3.22 × IPN Peak value ±10 % Accuracy @ IPN X % of IPN −1.25 1.25 Accuracy @ IPN @ TA = +105 °C X % of IPN −4.80 4.80 See formula note 3) Accuracy @ IPN @ TA = +85 °C X % of IPN −3.91 3.91 See formula note 3) Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases 3) TCIOE Accuracy @ X TA (% of IPN) = X + ( TCG × (TA – 25) + × 100 × (TA – 25)). 10000 1000 × IP 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 4/15 www.lem.com HO 60 .. 250-P series Electrical data HO 100-P-0100 At TA = 25 °C, UC = +5 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 13). Symbol Unit Primary nominal rms current Parameter IPN A Primary current, measuring range IPM A Number of primary turns NP - Supply voltage Min −250 250 1 UC V IC mA Reference voltage (output) Vref V 2.48 Reference voltage (input) Vref V 0.5 Output voltage range @ IPM Max Comment 100 Current consumption 1) Typ 4.5 @ UC ≥ 4.6 V See application information 5 5.5 19 25 2.5 2.52 Internal reference 2.65 External reference Vout − Vref V −2 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Allowed capacitive load CL nF 0 OCD output: On resistance Ron Ω 70 95 150 Open drain, active low Over operating temperature range OCD output: Hold time thold ms 0.7 1 1.4 Additional time after threshold has released EEPROM control Vout mV 0 50 Vout forced to GND when EEPROM in an error state 2) Electrical offset voltage @ IP = 0 A VOE mV −5 5 Vout − Vref @ Vref = 2.5 V Electrical offset current Referred to primary IOE A −0.625 0.625 Temperature coefficient of Vref TCVref ppm/K −170 170 −40 °C … 105 °C Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 −40 °C … 105 °C Offset drift referred to primary @ IP = 0 A TCIOE mA/K −9.375 9.375 −40 °C … 105 °C Theoretical sensitivity Gth mV/A Sensitivity error @ IPN εG % −0.5 0.5 Factory adjustment (straight bus bar) TCG ppm/K −350 350 −40 °C … 105 °C Linearity error 0 … IPN εL % of IPN −0.5 0.5 Linearity error 0 … IPM Temperature coefficient of G 2 Over operating temperature range 200 300 Series 2 5 Series 6 800 mV @ IPN 8 εL % of IPM −0.5 0.5 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.92 0.92 One turn Reaction time @ 10 % of IPN tra µs 2.5 @ 50 A/µs 3.5 @ 50 A/µs Response time @ 90 % of IPN tr µs Frequency bandwidth (−3 dB) BW kHz Output rms voltage noise (spectral density) (100 Hz … 100 kHz) eno µV/√ Hz Output voltage noise (DC … 10 kHz) (DC … 100 kHz) (DC … 1 MHz) Vno mVpp Over-current detect A 100 Small signals 6 3.6 8.7 16.9 2.64 × IPN 2.93 × IPN 3.22 × IPN Peak value ±10 % Accuracy @ IPN X % of IPN −1 1 Accuracy @ IPN @ TA = +105 °C X % of IPN −4.55 4.55 See formula note 3) Accuracy @ IPN @ TA = +85 °C X % of IPN −3.66 3.66 See formula note 3) Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases TCIOE 3) Accuracy @ X TA (% of IPN) = X + ( TCG × (TA – 25) + × 100 × (TA – 25)). 10000 16July2015/Version 5 1000 × IP LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 5/15 www.lem.com HO 60 .. 250-P series Electrical data HO 120-P-0100 At TA = 25 °C, UC = +5 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 13). Symbol Unit Primary nominal rms current Parameter IPN A Primary current, measuring range IPM A Number of primary turns NP - Supply voltage Min −300 300 1 UC V IC mA Reference voltage (output) Vref V 2.48 Reference voltage (input) Vref V 0.5 Output voltage range @ IPM Max Comment 120 Current consumption 1) Typ 4.5 @ UC ≥ 4.6 V See application information 5 5.5 19 25 2.5 2.52 Internal reference 2.65 External reference Vout − Vref V −2 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Allowed capacitive load CL nF 0 OCD output: On resistance Ron Ω 70 95 150 Open drain, active low Over operating temperature range OCD output: Hold time thold ms 0.7 1 1.4 Additional time after threshold has released EEPROM control Vout mV 0 50 Vout forced to GND when EEPROM in an error state 2) Electrical offset voltage @ IP = 0 A VOE mV −5 5 Vout − Vref @ Vref = 2.5 V Electrical offset current Referred to primary IOE A −0.75 0.75 Temperature coefficient of Vref TCVref ppm/K −170 170 −40 °C … 105 °C Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 −40 °C … 105 °C Offset drift referred to primary @ IP = 0 A TCIOE mA/K −11.25 11.25 −40 °C … 105 °C Theoretical sensitivity Gth mV/A Sensitivity error @ IPN εG % −0.5 0.5 Factory adjustment (straight bus-bar) TCG ppm/K −350 350 −40 °C … 105 °C Temperature coefficient of G 2 Over operating temperature range 200 300 Series 2 5 Series 6 800 mV @ IPN 6.667 Linearity error 0 … IPN εL % of IPN −0.5 0.5 Linearity error 0 … IPM εL % of IPM −0.5 0.5 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.92 0.92 One turn Reaction time @ 10 % of IPN tra µs 2.5 @ 50 A/µs Response time @ 90 % of IPN tr µs 3.5 @ 50 A/µs Frequency bandwidth (−3 dB) BW kHz Output rms voltage noise (spectral density) (100 Hz … 100 kHz) eno µV/√ Hz Output voltage noise (DC … 10 kHz) (DC … 100 kHz) (DC … 1 MHz) Vno mVpp A 2.64 × IPN Accuracy @ IPN X % of IPN -1 1 Accuracy @ IPN @ TA = +105 °C X % of IPN -4.55 4.55 See formula note 3) Accuracy @ IPN @ TA = +85 °C X % of IPN -3.66 3.66 See formula note 3) Over-current detect 100 Small signals 5.3 3.2 7.5 14.6 2.93 × IPN 3.22 × IPN Peak value ±10 % Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases 3) TCIOE Accuracy @ X TA (% of IPN) = X + ( TCG × (TA – 25) + × 100 × (TA – 25)). 10000 1000 × IP 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 6/15 www.lem.com HO 60 .. 250-P series Electrical data HO 180-P-0100 At TA = 25 °C, UC = +5 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 13). Parameter Symbol Unit Primary nominal rms current IPN A Primary current, measuring range IPM A Min Max Comment 180 −450 Number of primary turns NP - Supply voltage 1) UC V Current consumption IC mA Reference voltage (output) Vref V 2.48 Reference voltage (input) Vref V 0.5 Output voltage range @ IPM Typ 450 1 4.5 @ UC ≥ 4.6 V See application information 5 5.5 19 25 2.5 2.52 Internal reference 2.65 External reference Vout − Vref V −2 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Allowed capacitive load CL nF 0 OCD output: On resistance Ron Ω 70 95 150 Open drain, active low Over operating temperature range OCD output: Hold time thold ms 0.7 1 1.4 Additional time after threshold has released EEPROM control Vout mV 0 50 Vout forced to GND when EEPROM in an error state 2) Electrical offset voltage @ IP = 0 A VOE mV −5 5 Vout − Vref @ Vref = 2.5 V Electrical offset current Referred to primary IOE A −1.13 1.13 Temperature coefficient of Vref TCVref ppm/K −170 170 −40 °C … 105 °C Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 −40 °C … 105 °C Offset drift referred to primary @ IP = 0 A TCIOE mA/K −16.9 16.9 −40 °C … 105 °C Gth mV/A Theoretical sensitivity Sensitivity error @ IPN εG Temperature coefficient of G 2 Over operating temperature range 200 300 Series 2 5 Series 6 800 mV @ IPN 4.444 % −0.5 0.5 Factory adjustment (straight bus-bar) −40 °C … 105 °C TCG ppm/K −350 350 Linearity error 0 … IPN εL % of IPN −0.5 0.5 Linearity error 0 … IPM εL % of IPM −0.5 0.5 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.92 0.92 One turn Reaction time @ 10 % of IPN tra µs 2.5 @ 50 A/µs 3.5 @ 50 A/µs Response time @ 90 % of IPN tr µs Frequency bandwidth (−3 dB) BW kHz Output rms voltage noise (spectral density) (100 Hz … 100 kHz) eno µV/√ Hz Output voltage noise (DC … 10 kHz) (DC … 100 kHz) (DC … 1 MHz) Vno mVpp Over-current detect A 100 Small signals 4 2.7 5.4 10.8 2.64 × IPN 2.93 × IPN 3.22 × IPN Peak value ±10 % Accuracy @ IPN X % of IPN −1 1 Accuracy @ IPN @ TA = +105 °C X % of IPN −4.55 4.55 See formula note 3) Accuracy @ IPN @ TA = +85 °C X % of IPN −3.66 3.66 See formula note 3) Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases TCIOE 3) Accuracy @ X TA (% of IPN) = X + ( TCG × (TA – 25) + × 100 × (TA – 25)). 10000 16July2015/Version 5 1000 × IP LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 7/15 www.lem.com HO 60 .. 250-P series Electrical data HO 240-P-0100 At TA = 25 °C, UC = +5 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 13). Symbol Unit Primary nominal rms current Parameter IPN A Primary current, measuring range IPM A Number of primary turns NP - Supply voltage Min Typ Max Comment 240 −600 600 1 See application information UC V Current consumption IC mA Reference voltage (output) Vref V 2.48 Reference voltage (input) Vref V 0.5 Vout − Vref V −2 2 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Allowed capacitive load CL nF 0 OCD output: On resistance Ron Ω 70 95 150 Open drain, active low Over operating temperature range OCD output: Hold time thold ms 0.7 1 1.4 Additional time after threshold has released EEPROM control Vout mV 0 50 Vout forced to GND when EEPROM in an error state 2) Electrical offset voltage @ IP = 0 A VOE mV −5 5 Vout − Vref @ Vref = 2.5 V Electrical offset current Referred to primary IOE A −1.5 1.5 Temperature coefficient of Vref TCVref ppm/K −170 170 −40 °C … 105 °C Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 −40 °C … 105 °C Offset drift referred to primary @ IP = 0 A TCIOE mA/K −22.5 22.5 −40 °C … 105 °C Theoretical sensitivity Gth mV/A Sensitivity error @ IPN εG % −0.5 0.5 Factory adjustment (straight bus-bar) TCG ppm/K −350 350 −40 °C … 105 °C Linearity error 0 … IPN εL % of IPN −0.5 0.5 Linearity error 0 … IPM εL % of IPM −0.5 0.5 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.92 0.92 One turn Reaction time @ 10 % of IPN tra µs 2.5 @ 50 A/µs Response time @ 90 % of IPN tr µs 3.5 @ 50 A/µs 1) Output voltage range @ IPM Temperature coefficient of G 4.5 @ UC ≥ 4.6 V 5 5.5 19 25 2.5 2.52 Internal reference 2.65 External reference Over operating temperature range 200 300 Series 2 5 Series 6 800 mV @ IPN 3.333 Frequency bandwidth (−3 dB) BW kHz Output rms voltage noise (spectral density) (100 Hz … 100 kHz) eno µV/√ Hz Output voltage noise (DC … 10 kHz) (DC … 100 kHz) (DC … 1 MHz) Vno mVpp A 2.64 × IPN Accuracy @ IPN X % of IPN −1 1 Accuracy @ IPN @ TA = +105 °C X % of IPN −4.55 4.55 See formula note 3) Accuracy @ IPN @ TA = +85 °C X % of IPN −3.66 3.66 See formula note 3) Over-current detect 100 Small signals 3.5 2.5 5 8.7 2.93 × IPN 3.22 × IPN Peak value ±10 % Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases 3) TCIOE Accuracy @ X TA (% of IPN) = X + ( TCG × (TA – 25) + × 100 × (TA – 25)). 10000 1000 × IP 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 8/15 www.lem.com HO 60 .. 250-P series Electrical data HO 250-P-0100 At TA = 25 °C, UC = +5 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 13). Parameter Symbol Unit Primary nominal rms current IPN A Primary current, measuring range IPM A Number of primary turns NP - Supply voltage Min Typ Max Comment 250 −625 625 1 See application information UC V Current consumption IC mA Reference voltage (output) Vref V 2.48 Reference voltage (input) Vref V 0.5 2.65 Vout − Vref V −2 2 Vref output resistance Rref Ω 130 Vout output resistance Rout Ω Allowed capacitive load CL nF 0 OCD output: On resistance Ron Ω 70 95 150 Open drain, active low Over operating temperature range OCD output: Hold time thold ms 0.7 1 1.4 Additional time after threshold has released EEPROM control Vout mV 0 50 Vout forced to GND when EEPROM in an error state 2) Electrical offset voltage @ IP = 0 A VOE mV −5 5 Vout − Vref @ Vref = 2.5 V Electrical offset current Referred to primary IOE A −1.57 1.57 Temperature coefficient of Vref TCVref ppm/K −170 170 −40 °C … 105 °C Temperature coefficient of VOE TCVOE mV/K −0.075 0.075 −40 °C … 105 °C Offset drift referred to primary @ IP = 0 A TCIOE mA/K −23.5 23.5 −40 °C … 105 °C Gth mV/A 1) Output voltage range @ IPM Theoretical sensitivity Sensitivity error @ IPN εG Temperature coefficient of G 4.5 @ UC ≥ 4.6 V 5 5.5 19 25 2.5 2.52 Internal reference External reference Over operating temperature range 200 300 Series 2 5 Series 6 800 mV @ IPN 3.2 % −0.5 0.5 Factory adjustment (straight bus-bar) −40 °C … 105 °C TCG ppm/K −350 350 Linearity error 0 … IPN εL % of IPN −0.5 0.5 Linearity error 0 … IPM εL % of IPM −0.5 0.5 Magnetic offset current (@ 10 × IPN) referred to primary IOM A −0.92 0.92 One turn Reaction time @ 10 % of IPN tra µs 2.5 @ 50 A/µs 3.5 @ 50 A/µs Response time @ 90 % of IPN tr µs Frequency bandwidth (−3 dB) BW kHz Output rms voltage noise (spectral density) (100 Hz … 100 kHz) eno µV/√ Hz Output voltage noise (DC … 10 kHz) (DC … 100 kHz) (DC … 1 MHz) Vno mVpp Over-current detect A 100 Small signals 3.5 2.5 5 8.7 2.64 × IPN 2.93 × IPN 3.22 × IPN Peak value ±10 % Accuracy @ IPN X % of IPN −1 1 Accuracy @ IPN @ TA = +105 °C X % of IPN −4.55 4.55 See formula note 3) Accuracy @ IPN @ TA = +85 °C X % of IPN −3.66 3.66 See formula note 3) Notes: 1) 3.3 V SP version available 2) EEPROM in an error state makes the transducer behave like a reverse current saturation. Use of the OCD may help to differentiate the two cases 3) TCIOE Accuracy @ X TA (% of IPN) = X + ( TCG × (TA – 25) + × 100 × (TA – 25)). 10000 1000 × IP 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 9/15 www.lem.com HO 60 .. 250-P series HO-P series, measuring range versus external reference voltage HO 60-P HO 100-P 400 600 500 300 400 Uc = 5 V Uc = 4.75 V Uc = 4.6 V 200 0 Uc = 5 V Uc = 4.75 V Uc = 4.6 V 300 200 Ip (A) Ip (A) 100 100 0 -100 -100 -200 -200 -300 -400 -300 -500 -400 0.5 1 1.5 2 -600 2.5 0.5 1 Vref (V) 1.5 2 2.5 Vref (V) HO 120-P HO 180-P 700 600 500 400 300 200 100 0 -100 -200 -300 -400 -500 -600 -700 700 600 500 400 300 200 100 0 -100 -200 -300 -400 -500 -600 -700 Uc = 5 V Uc = 4.75 V Uc = 4.6 V Ip (A) Ip (A) Uc = 5 V Uc = 4.75 V Uc = 4.6 V 0.5 1 1.5 2 0.5 2.5 1 1.5 2 2.5 Vref (V) Vref (V) HO 240-P HO 250-P 700 600 500 400 300 200 100 0 -100 -200 -300 -400 -500 -600 -700 700 600 500 400 300 200 100 0 -100 -200 -300 -400 -500 -600 -700 Uc = 5 V Uc = 4.75 V Uc = 4.6 V Ip (A) Ip (A) Uc = 5 V Uc = 4.75 V Uc = 4.6 V 0.5 1 1.5 2 Vref (V) 2.5 0.5 1 1.5 2 2.5 Vref (V) Page 10/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HO 60 .. 250-P series Maximum continuous DC current For all ranges: 300 250 HO 60-P HO 100-P HO 120-P HO 180-P HO 240-P HO 250-P Ip (A) 200 150 100 50 0 -40 -20 0 20 40 60 80 100 120 140 TA (°C) Important notice: whatever the usage and/or application, the transducer primary bar / jumper temperature shall not go above the maximum rating of 120 °C as stated in page 2 of this datasheet. Page 11/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HO 60 .. 250-P series HO-P series: name and codification HO family products may be ordered on request 1) with a dedicated setting of the parameters as described below (standards products are delivered with the setting 0100 according to the table). HO-P-XXXX Internal reference 2) 0 2.5 V 1 1.65 V 2 1.5 V 3 0.5 V 4 External Vref only Response time 0 4 µs 1 3.5 µs 2 6 µs Over current detection (× IPN ) 3) 0 2.93 A 0.68 1 3.59 B 0.93 2 3.99 C 1.17 3 4.77 D 1.44 4 5.19 E 1.60 5 5.76 F 1.91 6 1.68 G 2.08 7 2.35 H 2.31 EEPROM Control 0 YES 1 NO Standards products are: - HO 60-P-0100 - HO 100-P-0100 - HO 120-P-0100 - HO 180-P-0100 - HO 240-P-0100 - HO 250-P-0100 Notes: 1) 2) For dedicated settings, minimum quantities apply, please contact your local LEM support Vref electrical data Vref (V) TCVref (ppm/K) Vref parameter min typ max min max 0 2.48 2.5 2.52 −170 -70 1 1.63 1.65 1.67 −170 170 2 1.48 1.5 1.52 −170 170 3 0.49 0.5 0.51 −250 250 3) OCD (× IPN) correction table versus range and temperature. All other values or empty cells: no change HO-P-010x OCD Parameter A B C D E 6 F G H 7 0 1 2 3 4 5 IPN (A) all temperatures 120 180 240 250 Tolerance on OCD value ±20 % 5.10 6.7 - 5.60 7.30 - ±15 % ±10 % - No change Do not use Page 12/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HO 60 .. 250-P series Application information HOxx-P series is designed to use a bus-bar or a cable 1) to carry the current through out the aperture with a maximum capacity of 15 × 8 mm. The 2 jumpers should be used as mechanical fixation on the PCBA and must be kept in open circuit. HO-P series: output compatibility with HAIS series IPN (A) IPM (A) IPM / IPN Vout −Vref @ IPN (V) HO 60-P 60 150 2.5 0.8 HO 100-P 100 250 2.5 0.8 HO 120-P 120 300 2.5 HO 180-P 180 450 2.5 HO 240-P 240 600 HO 250-P 250 625 Reference IPN (A) IPM (A) IPM / IPN Vout − Vref @ IPN (V) HAIS 50-P 50 150 3 0.625 0.8 HAIS 100-P 100 300 3 0.625 0.8 HAIS 150-P 150 450 3 0.625 2.5 0.8 HAIS 200-P 200 600 3 0.625 2.5 0.8 Reference The HO-P gives the same output levels as the HAIS-P referring to the HAIS nominal currents. This allows easier replacement of HAIS by HO-P in existing applications. Note: 1) The maximum magnetic offset referred to primary is inversely proportional to the number of turns, thus is divided by 2 with 2 turns. Definition of typical, minimum and maximum values Minimum and maximum values for specified limiting and safety conditions have to be understood as such as well as values shown in “typical” graphs. On the other hand, measured values are part of a statistical distribution that can be specified by an interval with upper and lower limits and a probability for measured values to lie within this interval. Unless otherwise stated (e.g. “100 % tested”), the LEM definition for such intervals designated with “min” and “max” is that the probability for values of samples to lie in this interval is 99.73 %. For a normal (Gaussian) distribution, this corresponds to an interval between −3 sigma and +3 sigma. If “typical” values are not obviously mean or average values, those values are defined to delimit intervals with a probability of 68.27 %, corresponding to an interval between −sigma and +sigma for a normal distribution. Typical, maximal and minimal values are determined during the initial characterization of the product. Remark Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: Products/Product Documentation Safety This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock. When operating the transducer, certain parts of the module can carry hazardous voltage (e.g. primary bus bar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 13/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HO 60 .. 250-P series PCB Footprint in mm. Assembly on PCB ●● Recommended PCB hole diameter ●● Maximum PCB thickness ●● Wave soldering profile No clean process only 2.15 mm for primary pin 0.9 mm for secondary pin 2.4 mm maximum 260 °C, 10 s Insulation distance (nominal values): dCp dCI On PCB: A - B 18.85 mm - Between jumper and secondary pin 21.1 mm 20.9 mm Between primary busbar and secondary pin 14.6 mm - Between primary busbar and jumper - 8 mm Between primary busbar and core - 11.34 mm Between core and secondary terminal - 1.18 mm Page 14/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com HO 60 .. 250-P series Dimensions HO-P series (mm, general linear tolerance ±0.3 mm) Connection Ip Vref Vout Uc Remark: ●● VOUT is positive with respect to Vref when positive IP flows in direction of the arrow shown on the drawing above. Page 15/15 16July2015/Version 5 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
HO 60-P-0100 价格&库存

很抱歉,暂时无法提供与“HO 60-P-0100”相匹配的价格&库存,您可以联系我们找货

免费人工找货